988 resultados para oral fluid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Police services in a number of Australian states and overseas jurisdictions have begun to implement or consider random road-side drug testing of drivers. This paper outlines research conducted to provide an estimate of the extent of drug driving in a sample of Queensland drivers in regional, rural and metropolitan areas. Oral fluid samples were collected from 2657 Queensland motorists and screened for illicit substances including cannabis (delta 9 tetrahydrocannibinol [THC]), amphetamines, ecstasy, and cocaine. Overall, 3.8% of the sample (n = 101) screened positive for at least one illicit substance, although multiple drugs were identified in a sample of 23 respondents. The most common drugs detected in oral fluid were ecstasy (n = 53), and cannabis (n = 46) followed by amphetamines (n = 23). A key finding was that cannabis was confirmed as the most common self-reported drug combined with driving and that individuals who tested positive to any drug through oral fluid analysis were also more likely to report the highest frequency of drug driving. Furthermore, a comparison between drug vs. drink driving detection rates for one region of the study, revealed a higher detection rate for drug driving (3.8%) vs. drink driving (0.8%). This research provides evidence that drug driving is relatively prevalent on Queensland roads, and may in fact be more common than drink driving. This paper will further outline the study findings’ and present possible directions for future drug driving research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Threo-methylphenidate is a chiral psychostimulant drug widely prescribed to treat attention-deficit hyperactivity disorder in children and adolescents. An enantioselective CE-based assay with head-column field-amplified sample stacking for analysis of threo-methylphenidate enantiomers in liquid/liquid extracts of oral fluid is described. Analytes are electrokinetically injected across a short water plug placed at the capillary inlet and become stacked at the interface between plug and buffer. Enantiomeric separation occurs within a few minutes in a pH 3.0 phosphate/triethanolamine buffer containing 20 mg/mL (2-hydroxypropyl)-β-CD as chiral selector. The assay with six point multilevel internal calibration provides a linear response for each enantiomer in the 10-200 ng/mL concentration range, is simple, inexpensive, and reproducible, and has an LOQ of 5 ng/mL. It was applied to oral fluid patient samples that were collected up to 12 h after intake of an immediate release tablet and two different extended release formulations with racemic methylphenidate. Drug profiles could thereby be assessed in a stereoselective way. Almost no levorotary threo-methylphenidate enantiomer was detected after intake of the two extended release formulations, whereas this enantiomer was detected during the first 2.5 h after intake of the immediate release preparation. The noninvasive collection of oral fluid is an attractive alternative to plasma for the monitoring of methylphenidate exposure in the pediatric community.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the absence of effective vaccine(s), control of African swine fever caused by African swine fever virus (ASFV) must be based on early, efficient, cost-effective detection and strict control and elimination strategies. For this purpose, we developed an indirect ELISA capable of detecting ASFV antibodies in either serum or oral fluid specimens. The recombinant protein used in the ELISA was selected by comparing the early serum antibody response of ASFV-infected pigs (NHV-p68 isolate) to three major recombinant polypeptides (p30, p54, p72) using a multiplex fluorescent microbead-based immunoassay (FMIA). Non-hazardous (non-infectious) antibody-positive serum for use as plate positive controls and for the calculation of sample-to-positive (S:P) ratios was produced by inoculating pigs with a replicon particle (RP) vaccine expressing the ASFV p30 gene. The optimized ELISA detected anti-p30 antibodies in serum and/or oral fluid samples from pigs inoculated with ASFV under experimental conditions beginning 8 to 12 days post inoculation. Tests on serum (n = 200) and oral fluid (n = 200) field samples from an ASFV-free population demonstrated that the assay was highly diagnostically specific. The convenience and diagnostic utility of oral fluid sampling combined with the flexibility to test either serum or oral fluid on the same platform suggests that this assay will be highly useful under the conditions for which OIE recommends ASFV antibody surveillance, i.e., in ASFV-endemic areas and for the detection of infections with ASFV isolates of low virulence.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Studies amongst older people with acute dysphagic stroke requiring thickened fluids have assessed fluid intakes from combinations of beverage, food, enteral and parenteral sources, but not all sources simultaneously. The study aimed to comprehensively assess total water intake from food, beverages, enteral and parenteral sources amongst dysphagic adult in-patients receiving thickened fluids. Methods Patients requiring thickened fluid following dysphagia diagnosis were recruited consecutively from a tertiary teaching hospital’s medical and neurosurgical wards. Fluid intake from food and beverages was assessed by wastage, direct observation and quantified from enteral and parenteral sources through clinical medical records. Results No patients achieved their calculated fluid requirements unless enteral or parenteral fluids were received. The mean daily fluid intake from food was greater than from beverages whether receiving diet alone (food 807±363mL, food and beverages 370±179mL, p<0.001) or diet with enteral or parenteral fluid support (food 455±408mL, food and beverages 263±232mL, p<0.001). Greater daily fluid intakes occurred when receiving enteral and parenteral fluid in addition to oral dietary intake, irrespective of age group, whether assistance was required, diagnosis and whether stage 3 or stage 2 thickened fluids were required (p<0.05). After enteral and parenteral sources, food provided the most important contribution to daily fluid intakes. Conclusions The greatest contribution to oral fluid intake was from food, not beverages. Designing menus and food services which promote and encourage the enjoyment of fluid dense foods, in contrast to thickened beverages, may present an important way to improve fluid intakes of those with dysphagia. Supplemental enteral or parenteral fluid may be necessary to achieve minimum calculated fluid requirements.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: We have previously shown the high prevalence of oral anti-human papillomavirus type 16 (HPV-16) antibodies in women with HPV-associated cervical neoplasia. It was postulated that the HPV antibodies were initiated after HPV antigenic stimulation at the cervix via the common mucosal immune system. The present study aimed to further evaluate the effectiveness of oral fluid testing for detecting the mucosal humoral response to HPV infection and to advance our limited understanding of the immune response to HPV. Methods: The prevalence of oral HPV infection and oral antibodies to HPV types 16, 18 and 11 was determined in a normal, healthy population of children, adolescents and adults, both male and female, attending a dental clinic. HPV types in buccal cells were determined by DNA sequencing. Oral fluid was collected from the gingival crevice of the mouth by the OraSure method. HPV-16, HPV-18 and HPV-11 antibodies in oral fluid were detected by virus-like particle-based enzyme-linked immunosorbent assay. As a reference group 44 women with cervical neoplasia were included in the study. Results: Oral HPV infection was h ighest in children (9/114, 7.9%), followed by adolescents (4/78, 5.1%), and lowest in normal adults (4/116, 3.5%). The predominant HPV type found was HPV-13 (7/22, 31.8%) followed by HPV-32 (5/22, 22.7%). The prevalence of oral antibodies to HPV-16, HPV-18 and HPV-11 was low in children and increased substantially in adolescents and normal adults. Oral HPV-16 IgA was significantly more prevalent in women with cervical neoplasia (30/44, 68.2%) than the women from the dental clinic (18/69, 26.1% P = 0.0001). Significantly more adult men than women displayed oral HPV-16 IgA (30/47 compared with 18/69, OR 5.0, 95% CI 2.09-12.1, P < 0.001) and HPV-18 IgA (17/47 compared with 13/69, OR 2.4, 95% CI 0.97-6.2, P = 0.04). Conclusion: The increased prevalence of oral HPV antibodies in adolescent individuals compared with children was attributed to the onset of sexual activity. The increased prevalence of oral anti-HPV IgA in men compared with women was noteworthy considering reportedly fewer men than women make serum antibodies, and warrants further investigation. © 2006 Marais et al; licensee BioMed Central Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this investigation is to present an overview of roadside drug driving enforcement and detections in Queensland, Australia since the introduction of oral fluid screening. Drug driving is a problematic issue for road safety and investigations of the prevalence and impact of drug driving suggest that, in particular, the use of illicit drugs may increase a driver’s involvement in a road crash when compared to a driver who is drug free. In response to the potential increased crash involvement of drug impaired drivers, Australian police agencies have adopted the use of oral fluid analysis to detect the presence of illicit drugs in drivers. This paper describes the results of roadside drug testing for over 80,000 drivers in Queensland, Australia, from December 2007 to June 2012. It provides unique data on the prevalence of methamphetamine, cannabis and ecstasy in the screened population for the period. When prevalence rates are examined over time, drug driving detection rates have almost doubled from around 2.0% at the introduction of roadside testing operations to just under 4.0% in the latter years. The most common drug type detected was methamphetamine (40.8%) followed by cannabis (29.8%) and methamphetamine/cannabis combination (22.5%). By comparison, the rate of ecstasy detection was very low (1.7%). The data revealed a number of regional, age and gender patterns and variations of drug driving across the state. Younger drivers were more likely to test positive for cannabis whilst older drivers were more likely to test positive for methamphetamine. The overall characteristics of drivers who tested positive to the presence of at least one of the target illicit drugs are they are likely to be male, aged 30-39 years, be driving a car on Friday, Saturday or Sunday between 6:00PM and 6:00AM and to test positive for methamphetamine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Saliva as a biological fluid is gaining wider acceptance for diagnosing diseases. The growing interest in saliva as a biological fluid is due to its noninvasiveness, ease of use, cost-effectiveness, and multiple sample collection possibilities as well as minimal risk to health care professionals of contracting infectious organisms such as HIV and Hep B. However, the clinical translation of saliva is hampered by our lack of understanding of the biomolecular transportation from blood into saliva, the diurnal variations of biomolecules present in saliva, and relatively low levels of analytes (100th to a 1000th fold less than in blood). We provide information on the current status of salivary research, salivary diagnostics empowered by nanotechnology, and future prospects in this emerging field of saliva diagnostics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study sought to explore the initial impact of the ACT's implementation of roadside oral fluid drug screening program. The results suggest that a number of individuals reported intentions to drug drive in the future. The classical deterrence theory variables of certainty of apprehension, severity and swiftness of sanctions were not predictive of intentions to drug drive in the future. In contrast, having avoided apprehension and having known of others that have avoided apprehension were predictive of intentions to drug drive in the future. Increasing perceptions of the certainty of apprehension, increased testing frequency, and increased awareness of the oral fluid drug screening program could potentially lead to reductions of drug driving and result in safer road environment for all ACT community members.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Human papilloma virus (HPV) infection is a major risk factor for a distinct subset of head and neck squamous cell carcinoma (HNSCC). The current review summarizes the epidemiology of HNSCC and the disease burden, the infectious cycle of HPV, the roles of viral oncoproteins, E6 and E7, and the downstream cellular events that lead to malignant transformation. Current techniques for the clinical diagnosis of HPV-associated HNSCC will also be discussed, that is, the detection of HPV DNA, RNA, and the HPV surrogate marker, p16 in tumor tissues, as well as HPV-specific antibodies in serum. Such methods do not allow for the early detection of HPV-associated HNSCC and most cases are at an advanced stage upon diagnosis. Novel noninvasive approaches using oral fluid, a clinically relevant biological fluid, allow for the detection of HPV and cellular alterations in infected cells, which may aid in the early detection and HPV-typing of HNSCC tumors. Noninvasive diagnostic methods will enable early detection and intervention, leading to a significant reduction in mortality and morbidity associated with HNSCC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The use of large-volume electrolyte balanced solutions as preparation for colonoscopy often results in poor patient compliance and acceptance. The tolerance, safety, and efficacy of high-versus low volume colon-cleansing methods as preparation for colonoscopy in children were compared by randomized operator-blinded trial. Methods: Twenty-nine children ages 3.6-14.6 years had either high-volume nasogastric balanced polyethylene glycol electrolyte lavage (20 ml/kg/h) until the effluent was clear (n = 15), or two oral doses of sodium phosphate solution (22.5-45 ml) separated by oral fluid intake (n = 14). Results: Both preparations were equally effective. The low-volume preparation was better tolerated and caused less discomfort that the high-volume preparation, judging by serial nurse observations. The incidence of abdominal symptoms, diarrhea, sleep disturbance, and vomiting was not significantly different between the two groups. Both groups had a small reduction in mean hematocrit and serum calcium levels. The sodium phosphate preparation caused increases in mean serum sodium concentrations from 140 to 145 mmol/L and serum phosphate concentrations from 1.41 to 2.53 mmol/L. Ten hours after the commencement of the preanesthetic fast, these concentrations had returned to normal. Conclusions: There are advantages in terms of tolerance, discomfort, and case of administration with acceptable colonic cleansing with the use of the less-invasive oral sodium phosphate low-volume colon-cleansing preparation in children. Safe use requires ensuring an adequate oral fluid intake during the preparation time and avoidance of use in patients with renal insufficiency.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Drug testing is used by employers to detect drug use by employees or job candidates. It can identify recent use of alcohol, prescription drugs, and illicit drugs as a screening tool for potential health and safety and performance issues. Urine is the most commonly used sample for illicit drugs. It detects the use of a drug within the last few days and as such is evidence of recent use; but a positive test does not necessarily mean that the individual was impaired at the time of the test. Abstention from use for three days will often produce a negative test result. Analysis of hair provides a much longer window of detection, typically 1 to 3 months. Hence the likelihood of a falsely negative test using hair is very much less than with a urine test. Conversely, a negative hair test is a substantially stronger indicator of a non-drug user than a negative urine test. Oral fluid (saliva) is also easy to collect. Drugs remain in oral fluid for a similar time as in blood. The method is a good way of detecting current use and is more likely to reflect current impairment. It offers promise as a test in post-accident, for cause, and on-duty situations. Studies have shown that within the same industrial settings, hair testing can detect twice as many drug users as urine testing. Copyright (C) 2012 John Wiley & Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The multi-target screening method described in this work allows the simultaneous detection and identification of 700 drugs and metabolites in biological fluids using a hybrid triple-quadrupole linear ion trap mass spectrometer in a single analytical run. After standardization of the method, the retention times of 700 compounds were determined and transitions for each compound were selected by a "scheduled" survey MRM scan, followed by an information-dependent acquisition using the sensitive enhanced product ion scan of a Q TRAP hybrid instrument. The identification of the compounds in the samples analyzed was accomplished by searching the tandem mass spectrometry (MS/MS) spectra against the library we developed, which contains electrospray ionization-MS/MS spectra of over 1,250 compounds. The multi-target screening method together with the library was included in a software program for routine screening and quantitation to achieve automated acquisition and library searching. With the help of this software application, the time for evaluation and interpretation of the results could be drastically reduced. This new multi-target screening method has been successfully applied for the analysis of postmortem and traffic offense samples as well as proficiency testing, and complements screening with immunoassays, gas chromatography-mass spectrometry, and liquid chromatography-diode-array detection. Other possible applications are analysis in clinical toxicology (for intoxication cases), in psychiatry (antidepressants and other psychoactive drugs), and in forensic toxicology (drugs and driving, workplace drug testing, oral fluid analysis, drug-facilitated sexual assault).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In Europe and the United States, the recreational use of gamma-hydroxy butyric acid (GHB) at dance clubs and "rave" parties has increased substantially. In addition, GHB is used to assist in the commission of sexual assaults. The aim of this controlled clinical study was to acquire pharmacokinetic profiles, detection times, and excretion rates in human subjects. Eight GHB-naïve volunteers were administered a single 25-mg/kg body weight oral dose of GHB, and plasma, urine, and oral fluid specimens were analyzed by using gas chromatography-mass spectrometry (GC-MS). Liquid-liquid extraction was performed after acid conversion of GHB to gamma-butyrolactone. Limits of quantitation of 0.1 (oral fluid), 0.2 (urine), and 0.5 microg/mL (plasma) could be achieved in the selected ion monitoring mode. GHB plasma peaks of 39.4 +/- 25.2 microg/mL (mean +/- SEM) occurred 20-45 min after administration. The terminal plasma elimination half-life was 30.4 +/- 2.45 min, the distribution volume 52.7 +/- 15.0 L, and the total clearance 1228 +/- 233 microL/min. In oral fluid, GHB could be detected up to 360 min, with peak concentrations of 203 +/- 92.4 microg/mL in the 10-min samples. In urine, 200 +/- 71.8 and 230 +/- 86.3 microg/mL, were the highest GHB levels measured at 30 and 60 min, respectively. Only 1.2 +/- 0.2% of the dose was excreted, resulting in a detection window of 720 min. Common side-effects were confusion, sleepiness, and dizziness; euphoria and change of vital functions were not observed. GHB is extensively metabolized and rapidly eliminated in urine and oral fluid. Consequently, samples should be collected as soon as possible after ingestion.